High Voltage 1000V DC Circuit Breaker 10A to 63A The SA-C63 is a DC circuit breaker dedicated to multi string photovoltaic installations. This circuit breaker is designed to protect the cables located between each string of photovoltaic modules and the photovoltaic inverter against overloads and short circuits (see application diagram). Combined with a switch , the SA-C63 will be installed in a string PV protection enclosure at the end of each string of photovoltaic modules. It can be locked (by a padlocking device) in OFF position as a safety measure for removal of the PV inverter. Since a fault current can flow in the reverse direction to the operating current, the SA-C63 can detect and protect against any bidirectional current. To ensure the safety of the installation, it is necessary, depending on the various types of application, to combine the SA-C63 with:a residual current device at the AC end a fault passage detector (insulation monitoring device) at the DC end an earth protection circuit breaker at the DC end In all cases, fast action on site will be required to clear the fault (protection not ensured in the event of a double fault). SA-C63 is not polarity sensitive: (+) and (-) wires can inversed without any risk. The SA-C63 is: delivered with three inter-pole barrier to provide increased isolation distance between two adjacent connectors. Technical data Position contact indication - suitability for isolation according to IEC/EN 60947-2 standard. The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety. Increased product service life thanks to fast closing independent of the speed of actuation of the toggle. Pre-wired product: Input / Output on the same side .
Type
SA-63
Standard
IEC60947-2/GB14048.2
Poles in series
2P
4P
Rated voltage
600VDC
1000VDC
Maximum current of shell
63A
Rated current
10A,16A,20A,25A,32A,40A,50A,63A
Rated insulation voltage
1200VDC
Rated impulse voltage
4KV
Breaking type
H
Breaking capacity
6KA
Run off power
100%
Curve type
B
trip type
Thermal magnetic type
service life
Mechanical life
Actual mean value
20000
Standard average
8500
Electrical life
Actual mean value
4000
Standard average
1500
Installation and environment
Protection level
Side IP40, terminal Port IP20
Wiring capacity
2.5-25mm2
Using ambient temperature
-25ºC~+70ºC
Storage environment temperature
-40ºC~+85ºC
Heat resistance
2 category, humidity 55ºC, relative humidity 95%
Anti vibration
2.6 IEC60068
Anti impact parameter
2.27 IEC60068